Outputting Data and Controlling Operation through EtherNet/IP
FQ2-S4 User’s Manual
337
Con
necting
throu
gh
Eth
e
rnet
9
Timeout
This parameter is displayed and can be set only
when [Handshake setting] is set to [Yes].
A timeout error will occur if there is no response
from the PLC within the time that is set.
• From when measurements are completed
until the DSA Bit turns ON
• From when the GATE flag turns ON until the
DSA Bit turns OFF
• From when the GATE flag turns OFF until the
DSA Bit turns ON
0.1 to 120.0 s (default: 10 s)
Data output period This parameter is displayed and can be set only
when [Handshake setting] is set to [No]. Set the
period for outputting measurement results.
Set a value that is longer that the GATE ON
output time and shorter than the measurement
interval of the Sensor.
2 to 5,000 ms (default: 40 ms)
GATE signal ON
period
This parameter is displayed and can be set only
when [Handshake setting] is set to [No].
Set the time to turn ON the GATE signal.
Set the time that is required for the PLC to read
the measurement results.
Set the cycle time of the PLC so that it is longer
than the packet interval (RPI).
1.0 to 1,000.0 ms (default: 20.0 ms)
Parameter
Description
Setting range
Important
Important
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......