PLC Link Connections
390
FQ2-S4 User’s Manual
●
Start Continuous Measurements (Command Code: 1020 0010)
Command (PLC to Vision Sensor)
Response (Vision Sensor to PLC)
●
End Continuous Measurements (Command Code: 1030 0010)
Command (PLC to Vision Sensor)
Response (Vision Sensor to PLC)
First word of
command
area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
0001
0000
0010
0000
Command code
+3
0000
0000
0001
0000
First word of
response area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
0001
0000
0010
0000
Command code
The command code for which the
response applies is stored.
+3
0000
0000
0001
0000
+4
0000
0000
0000
0000
Response code
Command execution result
0: OK, FFFFFFFF: NG
+5
0000
0000
0000
0000
The measurement results are written to the output area if data output is set.
The measurement results are not output if data output is not set.
Setting the Data To Output Automatically after Measurements: p. 377
First word of
command
area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
0001
0000
0011
0000
Command code
+3
0000
0000
0001
0000
First word of
response area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
0001
0000
0011
0000
Command code
The command code for which the
response applies is stored.
+3
0000
0000
0001
0000
+4
0000
0000
0000
0000
Response code
Command execution result
0: OK, FFFFFFFF: NG
+5
0000
0000
0000
0000
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......