![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879192.webp)
Inspecting with the Labeling Inspection Item
190
FQ2-S4 User’s Manual
Unstable Labeling Results
The Desired Color Cannot Be Detected
Add a specific color or enlarge the color range.
Extraction Is Automatically Performed for an Undesired Color When Teaching
Manually set the color for which to measure the labeling.
[Inspect]
−
[Inspection]
−
[Area]
−
[Modify]
−
[Settings] Tab Page
−
[Teach]
• Sensors with Color Cameras Only
Item
Parameter
Setting
Description
Judgment
parameters
Number of
labels
Range: 0 to 100
Defaults: Upper limit: 100, Lower limit: 0
Set the upper and lower limits of the number of labels for
an OK judgement.
Total label area Range: 0 to 999,999,999.9999
Defaults: Upper limit: 999,999,999.999,
Lower limit: 0
Set the upper and lower limits of the total label area for
an OK judgement.
Area
Range: 0 to 999,999,999.9999
Defaults: Upper limit: 999,999,999.999,
Lower limit: 0
Sets the upper and lower limits of the area for an OK
judgement.
Gravity center
X
Range:
−
99,999.999 to 99,999.999
Defaults: Upper limit: 99,999.999,
Lower limit:
−
99,999.999
Set the upper and lower limits of the gravity X for an OK
judgement.
Gravity center
Y
Range:
−
99,999.999 to 99,999.999
Defaults: Upper limit: 99,999.999,
Lower limit:
−
99,999.999
Set the upper and lower limits of the gravity Y for an OK
judgement.
Master angle
Range:
−
180 to 180
Defaults: Upper limit: 180, Lower limit:
−
180
Sets the upper and lower limits of the master angle for an
OK judgement.
1
Press [
]
−
[Set color] on the right of the display.
2
Drag around the color for which you want to measure
the labeling.
Labeling with that color will be automatically detected.
Continuous measurements will be performed for the im-
ages that are displayed.
Only the extracted color will appear on the display.
3
Press [OK].
4
Press [TEACH].
5
Press [Back] to end teaching.
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......