![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879034.webp)
Part Names and Functions
32
FQ2-S4 User’s Manual
Sensor Data Units
No.
Name
Description
(1)
Sensor connector
Connects to the FQ2-S4.
(2)
Power supply and ground termi-
nal block
Connects to the 24-V power source and the ground line.
(3)
Parallel I/O connector
Connects to the I/O connector.
(4)
I/O indicators POWER/
ERROR
Lights green when power is being supplied.
Lights red when an error occurs.
RUN
Lights green during operation.
BUSY
Lights yellow when the Sensor is executing a process.
SENSOR
Lights yellow when the Sensor is connected.
OR-OK
Lights green when the overall judgement result is OK.
OR-NG
Lights red when the overall judgement result is OFF or an error occurs.
232C_COM
Lights yellow during RS-232C communications. (Provided only on the FQ-
SDU2
@
.)
(5)
DIN Track mounting section
Mounts the Data Unit to a DIN Track.
(6)
Slider
Used to secure the Data Unit to a DIN Track.
(7)
RS-232C connector
Connects to the RS-232C connector.
(8)
Parallel I/O connector
Connects to the I/O connector.
Front Surface of Parallel Interface
Sensor Data Unit
Back Surface of Parallel Interface
Sensor Data Unit
RS-232C Interface
Sensor Data Unit
(1)
(4)
(4)
(8)
(7)
(5)
(3)
(6)
(2)
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......