![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879390.webp)
PLC Link Connections
388
FQ2-S4 User’s Manual
Command Tables for PLC Link Communications
This section describes the commands used in PLC Link communications.
●
Measurement Control Commands
●
Utility Commands
●
Scene Control Commands
First word of com-
mand area (hex)
Command name
Function
Reference
+2
+3
1010
0010
Single Measurement
Performs a single measurement.
1020
0010
Start Continuous Measure-
ments
Executes continuous measurements.
1030
0010
End Continuous Measure-
ments
Ends continuous measurements.
First word of com-
mand area (hex)
Command name
Function
Reference
+2
+3
2010
0010
Clear Measurement Values
Clears all measurement result values.
3010
0010
Save Data in Sensor
Saves the current system data and scene
groups in the Sensor.
4010
0010
Re-register Model
Registers the model again.
4020
0010
External Teaching
Performs reteaching.
F010
0010
Reset Vision Sensor
Resets the Vision Sensor.
First word of com-
mand area (hex)
Command name
Function
Reference
+2
+3
1000
0020
Get Scene Number
Acquires the current scene number.
1000
0030
Select Scene
Changes to the specified scene number.
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......