![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879103.webp)
Reading and Verifying Character Strings
FQ2-S4 User’s Manual
4
Setting Up
Inspect
ions
101
Step 4 Setting the Verification Conditions
You can register a character string to use to verify that the character string that was read matches the registered char-
acter string. You can register up to 32 character strings for verification in the master data. You can verify the character
string in the inspection against up to 32 character strings that are registered in the master data. The verification result
is saved in an external reference parameter, so you can use a communications command to output it to an external
device.
External Reference Parameters: p. 491
[Inspect]
−
[Inspection]
−
[Add item.]
−
[OCR]
−
[Settings] Tab Page
You can specify whether to reflect the judgement result of the judgement conditions for character recognition in the
overall judgement. (The default is to reflect them.)
[Inspect]
−
[Inspection]
−
[Add item.]
−
[OCR]
−
[Details] Tab Page
−
[Output parameter]
−
[Reflect]
1
Press [Verification].
2
Press [Master data regist.].
3
Press the character string to register in the master
data.
4
You can use any of the following three methods to
register character strings in the master data from the
menu display.
[Auto]:
A character string is read from an image and
registered in the master data. The procedure
is essentially the same as the procedure for
teaching in step 2.
[Manual]: A character string is entered directly in the
master data. You can use a software key-
board to register a character string with up to
32 characters.
[Item ref.]: Select this item to use the immediately pre-
ceding read results as the verification charac-
ter string. The following inspection items can
be used as references: Bar code, 2D-code,
2D-code (DPM), and OCR. You cannot refer-
ence an inspection item that is after the cur-
rent inspection item. After a character string
is registered, a reference item number, such
as “Ref. 00,” will be displayed to the right of
the character string in the master data.
Note
You can set letters, numbers, symbols, and the following wild-
cards: * and ?.
*: A wildcard for a character string of 0 or more characters
?: A wildcard for one character
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......