![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879547.webp)
External Reference Parameters
FQ2-S4 User’s Manual
545
Ap
pend
ices
12
126
Mea-
sure-
ment
condi-
tions
Color deviation upper
limit
Setting/Acqui-
sition
0 to 221
221
---
---
127
Color deviation lower
limit
Setting/Acqui-
sition
0 to 221
0
---
---
130
Density average upper
limit
Setting/Acqui-
sition
0 to 255
255
---
---
131
Density average lower
limit
Setting/Acqui-
sition
0 to 255
0
---
---
132
Density deviation upper
limit
Setting/Acqui-
sition
0 to 127
127
---
---
133
Density deviation lower
limit
Setting/Acqui-
sition
0 to 127
0
---
---
134
R average upper limit
Setting/Acqui-
sition
0 to 255
255
---
---
135
R average lower limit
Setting/Acqui-
sition
0 to 255
0
---
---
136
G average upper limit
Setting/Acqui-
sition
0 to 255
255
---
---
137
G average lower limit
Setting/Acqui-
sition
0 to 255
0
---
---
138
B average upper limit
Setting/Acqui-
sition
0 to 255
255
---
---
139
B average lower limit
Setting/Acqui-
sition
0 to 255
0
---
---
310
Logging
condi-
tions
Entire Unit logging
switch
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
311
Judgement logging
switch
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
312
Average deviation/den-
sity average logging
switch
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
313
Color deviation/density
deviation logging switch
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
314
R average logging
switch
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
315
G average logging
switch
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
316
B average logging
switch
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
318
Standard deviation log-
ging switch
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
319
Density average differ-
ence logging switch
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
320
Density deviation differ-
ence logging switch
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
External
refer-
ence
number
Category Data name
Setting/Acqui-
sition
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......