![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879443.webp)
Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
FQ2-S4 User’s Manual
441
Con
necting
throu
gh
Eth
e
rnet
9
Getting the Inspection Item Data: 280F 00401020
This command acquires the parameters and measurement values of the specified inspection item.
●
Format
●
Response Format
●
End Codes
●
Parameter Descriptions
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
Inspection item number (4 bytes) External reference
number (4 bytes)
28
0F
00401020
Inspection item number from 00
to 1F (2 digits max.)
External reference
number
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
Acquired value (4
bytes)
28
0F
End code
00401020
Acquired value
(1,000 times the
actual value)
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Inspection item number
Specifies the number of the inspection item for which to acquire the data.
External reference num-
ber
Specifies the external reference number.
12-2 External Reference Parameters: p. 491
Acquired value
Returns the data for the specified inspection item.
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......