Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
304
FQ2-S4 User’s Manual
Parallel Judgement Outputs
You can set judgement conditions for parallel output and then output the judgement results for those conditions.
●
Setting the Items to Judge and the Judgement Conditions
You can assign up to 16 judgement results to and output them from the D0 to D15 signals.
As the items to judge, you can specify the measurement data from inspection items that can be output and the
calculation results from the expression settings.
Use the following procedure to set the items to judge and the judgment conditions.
(1)
Setting the Items to Judge
You can assign the parameters from the inspection items to the data output signals (D0 to D15).
The following procedure shows how to assign the measured position X of [0. Search] to D0.
[In/Out]
−
[I/O setting]
−
[Output data set]
−
[Par. Jdg Output]
−
[Basic] Tab Page
(2)
Setting the Judgement Conditions
[In/Out]
−
[I/O setting]
−
[Output data set]
−
[Par. Jdg Output]
−
[Basic] Tab Page
1
Press [Settings].
2
Press [I0.D0].
3
Press [IO. Search].
4
Press [Position X X].
5
If the inspection item allows multi-point output,
press the number ([0] to [30]) of the inspection result
for which to output the data from the list of inspec-
tion results.
To register something to D1 or higher, repeat this pro-
cess.
1
Press [Judgement condition].
2
Set the correlation range that is to be judged as OK.
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......