Outputting Data and Controlling Operation through EtherNet/IP
346
FQ2-S4 User’s Manual
Setting the Output Format
[In/Out]
−
[I/O setting]
−
[Output data setting]
−
[Link data output]
1
Press [Output format].
2
Press [Output form].
3
Set either a floating point decimal or a fixed decimal for the output form.
Outputting Character Strings
You can set whether to output the character string that results from reading. Outputting the character string is
possible for the following inspection results.
• OCR
• Bar code
• 2D-code
• 2D-code (DPM)
The procedure for outputting the character string is given here for two inspection items.
[In/Out]
−
[I/O setting]
−
[Output data set]
−
[Link data output]
−
[Output data set]
1
Select the inspection item for which to output the character string.
2
Set the following items on the setting display.
Item
Description
Setting range
Output form
Set the output form for numerical data.
Floating point or fixed point (default: Floating
point)
Parameter
Setting
Description
String output ON/OFF
OFF (default)
Yes
Sets whether to output the character string that results
from reading.
Partial output ON/OFF
No (default)
Yes
Sets whether to specify the range of characters to output.
Output string setup
1 to 128 for OCR
1 to 1024 for Bar code, 2D-
code, or 2D-code (DPM)
Sets the output range.
NG String output on/off
Yes (default)
No
Sets whether to output an NG string.
▲
▲
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......