![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879378.webp)
PLC Link Connections
376
FQ2-S4 User’s Manual
Item
Description
Setting range
Command (com-
mand area)
Area type
Select the area for the
Command Area in the
PLC.
If PLC Link (SYSMAC) is selected:
CIO Area (CIO)
Work Area (WR)
Holding Bit Area (HR)
Auxiliary Bit Area (AR)
DM Area (DM)
EM Area (EM0 to EMC)
Default: CIO Area (CIO)
If PLC Link (MELSEC) is selected:
Data Register (Data registers)
File Register (File registers)
Link Register (Link registers)
Default: Data Register
Address
Set the first address of the
command area in the PLC.
0 to 99,999
Default: 0
Response
(response area)
Area type
Set the PLC memory area
for the response area.
Same as for the Command Area.
Address
Set the first address of the
response area in the PLC.
0 to 99,999
Default: 100
Output (output
area)
Area type
Set the PLC memory area
for the output area.
Same as for the Command Area.
Address
Set the first address of the
output area in the PLC.
0 to 99,999
Default: 200
4
Set the communications protocol ([Comm. type]) to
PLC Link communications.
Item
Description
Setting range
Output handshake Enables or disables handshaking.
• Yes: Data is output when the DSA signal from the PLC turns
ON.
• No: Data is output regardless of the signal state from the PLC.
No or Yes
Default: No
Retry details
Enables or disables retrying communications.
ON or OFF
Default: OFF
Retry interval
Sets the interval for retrying communications.
This setting is enabled only when [Retry details] is set to [ON].
0 to 2,147,483,647 ms
Default:10,000 ms
Max output data
Sets the maximum data size that can be output at one time
through PLC Link communications. Set the number of bytes. Any
output data that is beyond this value is discarded.
32 to 1,024 bytes
Default: 256 bytes
Connection mode
Sets the TPC connection mode.
TCP server or TCP client
Default: TCP server
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...