Calibration
238
FQ2-S4 User’s Manual
2
Select the calibration pattern to use.
Select the calibration pattern to use from the calibration settings.
Selecting the Calibration Pattern to Use: p. 243
Setting the Calibration Pattern
Point Specification
Set the pixel coordinates of positions to set the calibration pattern.
When you enter the actual coordinates of the specified positions, the calibration parameters are automatically
calculated.
You can register the coordinates of up to 10 positions.
• Different Magnifications in X and Y Directions
Specify three positions.
(Setup
Mode)
−
[Calibration]
You can set the calibration setting for each scene.
You can use the same calibration setting for different scenes or use a different calibration setting for each scene.
If two positions are set, a lefthand coordinate system will be set (i.e., clockwise is the positive direction).
If you want to include the coordinate system in the calibration, specify three positions.
1
Select the data region to set from [Calibration data 0]
to [Calibration data 31].
2
Press [Modify].
3
Press
[
]
−
[Specify point] on the right of the display.
Note
Calibration
X : Y = 5 : 3
X : Y = 1 : 1
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......