External Reference Parameters
FQ2-S4 User’s Manual
507
Ap
pend
ices
12
170
Mea-
sure-
ment
condi-
tions
Noise level 1
Setting/Acqui-
sition
0 to 442
5
---
---
173
Monochrome density
change 1
Setting/Acqui-
sition
(Monochrome Cameras)
0: Light to Dark, 1: Dark to
Light
0
---
---
177
Measurement method
1
Setting/Acqui-
sition
(Monochrome Cameras)
0: Projection, 1: Differentia-
tion
0
---
---
180
Judge-
ment
condi-
tions
Edge position X upper
limit 0
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
181
Edge position X lower
limit 0
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
182
Edge position Y upper
limit 0
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
183
Edge position Y lower
limit 0
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
185
Edge position X upper
limit 1
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
186
Edge position X lower
limit 1
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
187
Edge position Y upper
limit 1
Setting/Acqui-
sition
−
|99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
188
Edge position Y lower
limit 1
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
190
Edge midpoint position
X upper limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
191
Edge midpoint position
X lower limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
192
Edge midpoint position
Y upper limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
193
Edge midpoint position
Y lower limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
194
Position compensation
X upper limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
195
Position compensation
X lower limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
196
Position compensation
Y upper limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
197
Position compensation
Y lower limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
External
refer-
ence
number
Category Data name
Setting/Acqui-
sition
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......