Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
292
FQ2-S4 User’s Manual
Controlling the Sensor from an External Device
The following Sensor functions can be controlled with command inputs from an external device without
connecting the Touch Finder.
Change to Expanded Mode before you input any command other than a command to change the scene. If you
change to Expanded Mode, you can use any of the commands. However, in Expanded Mode, you can change
to only 16 scenes with the parallel SCENE command instead of 32 scenes.
Changing the Scene
This section describes how to change the line process by changing the scene.
Wiring
Function
Description
Reference
Switching the scene
This command changes the scene when the line process changes.
Re-registering the model or refer-
ence color
This command re-registers the judgement references for measurement when lev-
els are changed.
Clearing an error
This command turns the ERROR signal OFF.
Continuous measurement
Continuous measurement is performed while this command is input.
Clearing measurement values
This command clears the measurement values.
Saving data in the Sensor
This command saves the settings data to the Sensor.
External teaching
This command executes teaching for all applicable inspection items.
Color
Signal
State
Description
The signals shown at the left
are used.
Refer to the following
information for signal wiring.
Input Mode
Standard Mode
Expanded Mode
Gray
IN0
Scene number
(0 to 31)
Scene number
(0 to 15)
Specifies the scene number.
IN0 to IN4 correspond to the binary
bits of the scene number.
To change to scene 1 in Standard
Mode, specify 00001.
Green
IN1
Red
IN2
White
IN3
Purple
IN4
ON
Yellow
IN5
ON
Trigger to change the scene
Orange
OUT1
(BUSY)
--
Processing in progress (default)
Important
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......