Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
FQ2-S4 User’s Manual
299
8
Controll
ing
Ope
rati
on a
nd Outputting
Data
wi
th
a
Para
llel
Co
nne
ctio
n
Save Data in Sensor
You can save the current settings (scene data and system data) in the Sensor.
Settings
[In/Out]
−
[I/O setting]
−
[I/O setting]
−
[Input]
−
[Input mode]
Press [Expand mode].
Wiring
Timing Chart
This function can be used in Run Mode only.
Color
Signal
State
Description
The signals shown at the left
are used.
Refer to the following
information for signal wiring.
Gray
IN0
ON
Command parameters for saving data to
the Sensor
Green
IN1
OFF
Red
IN2
OFF
White
IN3
OFF
Purple
IN4
OFF
Yellow
IN5
ON
Command input for saving data to the
Sensor
Orange
OUT1 (BUSY)
--
Processing in progress (default)
1 Turn ON IN0 and turn OFF IN1 to IN4.
2 Turn ON the IN5 signal while the
BUSY signal is OFF to save the data
in the Sensor.
Note
OFF
ON
Saving data
in Sensor started.
Saving data in
Sensor completed.
OFF
ON
BUSY
signal
IN5 signal
ON for 1 ms min.
Allow 5 ms min. and then
turn ON IN5.
IN0 to IN4
signals
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......