Controlling Operation and Outputting Data with TCP No-protocol Communications
410
FQ2-S4 User’s Manual
<Response Format>
If a parameter is attached, the parameter and delimiter are output when the command is processed normally,
and the command execution result is OK. A delimiter is inserted at the end of the response.
The delimiter is always CR.
Command Execution Result
Parameter
If the command is not processed normally, the command execution result is NG.
Command Execution Result
An error occurs in the following cases.
• A non-existent command was specified.
• The number of parameters is incorrect.
• The parameter range is incorrect.
• The parameter content is incorrect.
• Operation could not be performed normally for the operation command.
Delimiter
1
0
CR
Delimiter
O
K
CR
Delimiter
N
G CR