Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
324
FQ2-S4 User’s Manual
Input Signals
Clearing the OR and D Signals
This command clears the OR signal and D signals.
Parameters
Timing Chart
Signal
Function
IN0
Turn ON.
IN1 and IN2
Turn OFF.
IN3
Turn ON.
IN4 and IN5
Turn OFF.
IN6
Turn ON.
IN7
This signal is the trigger for executing teaching. Set the IN0 to IN6 signals, wait for at least 5 ms, and then turn
ON the IN7 signal. The BUSY signal will be ON while the command is being executed.
Execution
Command
Input example
IN7
IN6
IN5
IN4
IN3
IN2
IN1
IN0
1
1000010
11000010
ON for 1 ms min.
TRIG is input.
OR signal
BUSY signal
OFF
ON
OFF
ON
RUN signal
OFF
ON
TRIG signal
OFF
ON
Run Mode entered.
Setup Mode entered.
D signals
Measurements executed.
GATE signal
OFF
ON
Output time
1000010
GATE ON delay
IN0 to IN6
signals
IN7 signal
OFF
ON
Data
0
ACK signal
OFF
ON
ACK output time
Allow 5 ms min.
and then turn ON IN7.
ON for 1 ms min.
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......