![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879137.webp)
Reading DPM 2D Codes
FQ2-S4 User’s Manual
4
Setting Up
Inspect
ions
135
Changing the Character String That Is Output for Read Errors
You can change the character string that is output for read errors.
[Inspect]
−
[Inspection]
−
[Add item.]
−
[2D-code (DPM)]
−
[Details] Tab Page
−
[Output
parameter]
−
[Error string]
Measurement Data That Can Be Used for External Outputs and Calculations
Inspection Data that Can be Logged
The following values can be logged as inspection data.
When logging data is output, the data is output in the order of the above table.
7-6 Logging Measurement Data and Image Data: p. 252
Setup Item
Setting Value
Description
Error string
Max. 20 digits (default value:
NG)
Sets the text string to be output when a read error occurs.
Expression text
string
Data name
Description
Data range
JG
Judgment
This is the judgment result.
−
2: No judgment (not measured),
0: Judgment is OK,
−
1: Judgment is NG,
−
13: Teaching not performed error,
−
14: Figure not registered error,
−
15: Out of range error,
−
16: Measurement timeout error
IN
Index
The verification result (master data No.) is
output.
−
2: Verification OFF,
or reading error
−
1: Verification is NG,
0 to 31: Master data No.
N
Num. of characters
The number of characters read is output.
0 to 1024
E
Cell recognition rate
Outputs the cell recognition rate.
0 to 100
C
Contrast
Outputs the contrast.
0 to 100
F
Focus
Outputs the focus.
0 to 100
Inspection item
Value range
Description
Judgement
−
2: No judgement (not measured),
0: Judgement is OK,
−
1: Judgement is NG,
−
13: Teaching not performed error,
−
14: Figure not registered error,
−
15: Out of range error,
−
16: Measurement timeout error
This is the judgement result from the measurements.
Cell recognition rate
0 to 100
Outputs the cell recognition rate.
Contrast
0 to 100
Outputs the contrast.
Num. of char.
0 to 1024
Outputs the number of characters that were detected.
Index
−
2: Verification OFF, or reading error
−
1: Verification is NG,
0 to 31: Master data No.
Outputs the index.
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......