External Reference Parameters
FQ2-S4 User’s Manual
517
Ap
pend
ices
12
120
Mea-
sure-
ment
result
Code type
Set/acquired
0: Auto
1: DataMatrix
2: QR Code
0
---
---
121
Code color
Set/acquired
0: Auto
1: Black
2: White
0
---
---
122
Cell (DataMatrix
Square)
Set/acquired
0: Auto
1: 10
×
10
2: 12
×
12
...
16: 64
×
64
0
---
---
123
Cell (DataMatrix Rect-
angle)
Set/acquired
0: Auto
1: 8
×
18
2: 8
×
32
...
16: 16
×
64
0
---
---
124
Cell (QR Code)
Set/acquired
0: Auto
1: 21
×
21
2: 25
×
25
...
10: 57
×
57
0
---
---
127
Size
Set/acquired
50 to 480
480
---
---
128
Reverse
Set/acquired
0: Auto
1: Normal
2: Reverse
0
---
---
129
QR Code Model
Set/acquired
0: Auto
1: Model 1
2: Model 2
0
---
---
130
Error Correction Level
Set/acquired
0: Auto
1: M (15%)
2: L (7%)
3: H (30%)
4: Q (25%)
0
---
---
131
Mea-
sure-
ment
result
Timeout time (ms)
Setting/Acqui-
sition
1 to 9999
9999
---
---
132
Fast mode
Set/acquired
0: OFF 1: ON
0
---
---
133
Output
parame-
ter
String output on/off
Set/acquired
0: OFF 1: ON
0
---
---
134
Partial output on/off
Set/acquired
0: OFF 1: ON
0
---
---
135
Output end digit
Set/acquired
1 to 1024
1024
---
---
136
Output starting digit
Set/acquired
1 to 1024
1
---
---
137
Mea-
sure-
ment
result
Auto length
Set/acquired
0: OFF 1:ON
1
---
---
138
Output
parame-
ter
NG String output on/off Set/acquired
0: OFF 1: ON
0
---
---
140
Error string
Setting/Acqui-
sition
0: OFF 1: ON
0
---
---
External
refer-
ence
number
Category Data name
Set/acquired
Data range
Default
Text string
assigned
to
Ethernet
output
setting
Logged
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......