![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879425.webp)
Controlling Operation and Outputting Data with TCP No-protocol Communications
FQ2-S4 User’s Manual
423
Con
necting
throu
gh
Eth
e
rnet
9
Set Inspection Item Data
This command sets the parameters and measurement values of the specified inspection item.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Inspection item number
Specifies the inspection item number. (0 to 31)
External reference data
number
Specifies the external reference data number. (0 to 9999)
12-2 External Reference Parameters: p. 491
Acquired value
Returns the data for the specified inspection item.
12-2 External Reference Parameters: p. 491
I
T
D
A
T
A
Setting
CR
E
M
Inspection
item number
(2 digits max.)
Command
Space
(0x20)
Space
(0x20)
Space
(0x20)
Delimiter
Setting
Delimiter
External reference
data number
(4 digits max.)
External reference
data number
(4 digits max.)
Set value
Set value
Command
or
D
I
CR
Space
(0x20)
Space
(0x20)
Space
(0x20)
Inspection item
number
(2 digits max.)
CR
O
K
Delimiter
CR
E
R
Delimiter
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......