External Reference Parameters
528
FQ2-S4 User’s Manual
*1: To acquire the detected text string, use the ITEMDATA2 command.
1583+N
×
2 (N = 0
to 3)
Verification con-
ditions
Verification begin-
ning digit 29N
Setting/Acquisition
1 to 32
1
---
---
1591+N
×
2 (N = 0
to 3)
*1
Master data 29N
Setting/Acquisition
32 characters max.
---
---
1601
Reference unit
number 30
Setting/Acquisition
−
1: OFF,
0 to 31
−
1
1602+N
×
2 (N = 0
to 3)
Verification end
digit 30N
Setting/Acquisition
1 to 32
32
---
---
1603+N
×
2 (N = 0
to 3)
Verification begin-
ning digit 30N
Setting/Acquisition
1 to 32
1
---
---
1611+N
×
2 (N = 0
to 3)
*1
Master data 30N
Setting/Acquisition
32 characters max.
---
---
1621
Reference unit
number 31
Setting/Acquisition
−
1: OFF,
0 to 31
−
1
1622+N
×
2 (N = 0
to 3)
Verification end
digit 31N
Setting/Acquisition
1 to 32
32
---
---
1623+N
×
2 (N = 0
to 3)
Verification begin-
ning digit 31N
Setting/Acquisition
1 to 32
1
---
---
1631+N
×
2 (N = 0
to 3)
*1
Master data 31N
Setting/Acquisition
32 characters max.
---
---
2000
Measurement
result
Number of read
characters on line 1
Acquisition only
0 to 32
0
---
---
2001
Number of read
characters on line 2
Acquisition only
0 to 32
0
---
---
2002
Number of read
characters on line 3
Acquisition only
0 to 32
0
---
---
2003
Number of read
characters on line 4
Acquisition only
0 to 32
0
---
---
2100
Read character
string on line 1
Acquisition only
32 characters max.
---
---
---
2101
*1
Read character
string on line 2
Acquisition only
32 characters max.
---
---
---
2102
*1
Read character
string on line 3
Acquisition only
32 characters max.
---
---
---
2103
*1
Read character
string on line 4
Acquisition only
32 characters max.
---
---
---
2500+N
(N= 0 to
127)
Individual read
character
Acquisition only
1 character
---
---
---
3000+N
(N= 0 to
127)
Individual similarity
Acquisition only
0 to 100
0
---
---
3500+N
(N= 0 to
127)
Individual stability
Acquisition only
0 to 100
0
---
---
External
refer-
ence
number
Category
Data name
Setting/Acquisition
Data range
Default
Expres-
sion text
string
Logged
data/
Judge-
ment
parame-
ter
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...