Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
438
FQ2-S4 User’s Manual
Changing the Scene Number: 280F 00301000
This command changes the scene number to use.
●
Format
●
Response Format
●
End Codes
●
Parameter Descriptions
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
Scene number (4 bytes)
28
0F
00301000
Scene number to change to (2
digits max.)
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28
0F
End code
00301000
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Scene number
Specifies the scene number (0 to 31) to change to.