![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879515.webp)
External Reference Parameters
FQ2-S4 User’s Manual
513
Ap
pend
ices
12
125
Output
parame-
ter
String output on/off
Settings/
Acquisition
0: None
1: Enable
0
---
---
127
*1
Error string
Settings/
Acquisition
20 characters max
NG
---
---
128
Partial output on/off
Settings/
Acquisition
0: None
1: Enable
0
---
---
129
Output last digit
Settings/
Acquisition
1 to 1024
1024
---
---
130
Output first digit
Settings/
Acquisition
1 to 1024
1
---
---
131
Mea-
sure-
ment
result
Code type
Settings/
Acquisition
0: JAN/EAN/UPC
1: Code 39
2: Codabar
3: ITF
4: Code 93
5: Code128/GS1-128
6: GS1 DataBar
7: Pharmacode
0
---
---
132
Timeout time (ms)
Settings/
Acquisition
1 to 9999
9999
---
---
133
Check digit on/off
Settings/
Acquisition
0: None
1: Enable
1
---
---
134
Composite codes on/off Settings/
Acquisition
0: None
1: Enable
0
---
---
135
Direction
Settings/
Acquisition
0: Horizontal mode
1: Vertical mode
0
---
---
136
Reverse on/off
Settings/
Acquisition
0: None
1: Enable
0
---
---
150
Verifica-
tion con-
dition
Selected master num-
ber
Settings/
Acquisition
1 to 31
0
---
---
152
Auto master data num-
ber
Setting/Acqui-
sition
0 to 31: Master data num-
ber
−
1: OFF
−
1
---
---
170
Output
parame-
ter
String output ON/OFF
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON
0
---
---
171
NG error code output
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON
1
---
---
172
Partial output ON/OFF
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON
0
---
---
173
Output end digit (mem-
ory link)
Setting/Acqui-
sition
1 to 128
128
---
---
174
Output beginning digit
(memory link)
Setting/Acqui-
sition
1 to 128
1
---
---
202+3N
(N=0 to
31)
Verifica-
tion con-
dition
Master data N
Settings/
Acquisition
32 characters max.
None
---
---
300+N
(N=0 to
31)
Reference unit number
N
Setting/Acqui-
sition
0 to 31
0
---
---
410
Logging
condi-
tions
Data logging switch for
unit
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
411
Data logging switch for
judgement
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
412
Data logging switch for
number of characters
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1
---
---
External
refer-
ence
number
Category Data name
Setting/Acqui-
sition
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......