![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879363.webp)
Outputting Data and Controlling Operation through EtherNet/IP
FQ2-S4 User’s Manual
361
Con
necting
throu
gh
Eth
e
rnet
9
●
Reset Vision Sensor (Command Code: 0010 F010)
Command (PLC to Vision Sensor)
Response (Vision Sensor to PLC)
If you leave the EXE signal ON when you use it to execute the Reset command, the Vision Sensor will restart
repeatedly.
After you execute the Reset command, turn OFF the EXE signal before the Vision Sensor restarts.
●
Get Latest Error Information (Command Code: 0020 5000)
Command (PLC to Vision Sensor)
Response (Vision Sensor to PLC)
First word of
command
area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
1111
0000
0001
0000
Command code
+3
0000
0000
0001
0000
First word of
response area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
There is no response for a reset operation.
First word of
command
area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
0101
0000
0000
0000
Command code
+3
0000
0000
0010
0000
First word of
response area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
0101
0000
0000
0000
Command code
The command code for which the
response applies is stored.
+3
0000
0000
0010
0000
+4
0000
0000
0000
0000
Response code
Command execution result
0: OK, FFFFFFFF: NG
+5
0000
0000
0000
0000
+6
0000
0000
0000
0000
Response data
Latest error code
+7
0000
0000
0000
0000
Important
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......