Reading Bar Codes
FQ2-S4 User’s Manual
4
Setting Up
Inspect
ions
115
[Item ref.]: Select this item to use the immediately pre-
ceding read results as the verification char-
acter string. The following inspection items
can be used as references: Bar code, 2D-
code, 2D-code (DPM), and OCR. You can-
not reference an inspection item at an item
number that is after the item number of the
inspection item that you are editing. When
you register a character string from the mas-
ter data, the item number of the inspection
item that is being referenced, such as “Ref.
00,” will be displayed.
Using Item References: p. 101
5
Repeat the above procedure to register more than
one character string in the master data.
6
Press [Verif. master data] and select the character
string in the master data to use for verification.
7
Set the following verification conditions as required.
Setup Item
Setting Value
Description
Verif. master data
OFF (default value)
Sets whether to verify the character string that was read from the bar-
code against a character string that is registered in the master data. To
verify the read character string against the master data, select the char-
acter string to use for verification.
All master data
Master data 0 to 31
Partial verif. on/off
No (default value)
The number of digits in the read results to be verified with the master
data can be limited. When [Partial verification] is set to ON, set the first
and last compared digit positions. Up to 32 characters can be set as the
number of digits.
Example: First compared digit 2, last compared digit 6
The text string used for verification becomes "MRON2".
Yes
Partial verification setup
1 to 1024
(Default
First digit: 1, last digit: 1024)
Master data regist.
---
Registers a character string in the master data.
Auto teach No.
Off (default)
Sets the character string in which to automatically register the read
result for teaching from an external device.
Master data 0 to 31
Check the table of ASCII characters to see what characters can
be registered. You cannot enter two-byte characters, one-byte
Kana characters, and control codes. You can use the following
characters as wildcards.
*: A wildcard for a character string of 0 or more characters
?: A wildcard for one character
Note
O M R O N 2 0 0 8
2nd digit
6th digit
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......