Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
FQ2-S4 User’s Manual
289
8
Controll
ing
Ope
rati
on a
nd Outputting
Data
wi
th
a
Para
llel
Co
nne
ctio
n
• One-shot output
The status of the output OR signal is turned OFF after a specified time has passed. (Setting range: 0 to 1,000 ms)
Delaying the Output Timing
When using one-shot output, the output timing of the OR signal can be delayed. (Setting range: 0 to 1,000 ms)
Settings
[In/Out]
−
[I/O setting]
−
[I/O setting]
−
[Output]
1
Press [Output mode] and press [Level output] or
[One-shot output].
2
Press [Output delay] and set the one-shot output de-
lay.
3
Press [OK].
4
Press [Output time] and set the one-shot output time.
5
Press [OK].
OFF
ON
OFF
ON
OFF
ON
NG
OK
Turns OFF.
One-shot
output time
Overall judgement
(OR output: ON for NG)
OR signal
ON while
measurements are
being processed
(depends on BUSY
output conditions)
BUSY signal
TRIG signal
ON for 1 ms min.
OFF
ON
OFF
ON
OFF
ON
NG
One-shot
output time
Overall judgement
(OR output: ON for NG)
OR signal
ON while
measurements are
being processed
(depends on BUSY
output conditions)
BUSY signal
TRIG signal
ON for 1 ms min.
One-shot
output delay
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......