Outputting Data and Controlling Operation through EtherNet/IP
364
FQ2-S4 User’s Manual
Response (Vision Sensor to PLC)
●
Get Inspection Item Data (Command Code: 0040 1020)
Command (PLC to Vision Sensor)
Response (Vision Sensor to PLC)
First word of
response area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
0001
0000
0001
0000
Command code
The command code for which the
response applies is stored.
+3
0000
0000
0101
0000
+4
0000
0000
0000
0000
Response code
Command execution result
0: OK, FFFFFFFF: NG
+5
0000
0000
0000
0000
First word of
command
area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
0001
0000
0010
0000
Command code
+3
0000
0000
0100
0000
+4
0000
0000
0000
0000
Inspection item number
+5
0000
0000
0000
0000
+6
0000
0000
0000
0000
Data number
+7
0000
0000
0000
0000
First word of
response area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
0001
0000
0010
0000
Command code
The command code for which the
response applies is stored.
+3
0000
0000
0100
0000
+4
0000
0000
0000
0000
Response code
Command execution result
0: OK, FFFFFFFF: NG
+5
0000
0000
0000
0000
+6
0000
0000
0000
0000
Acquired data
(1,000 times the value)
+7
0000
0000
0000
0000
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......