![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879090.webp)
Adjusting the Images That Were Taken
88
FQ2-S4 User’s Manual
Y0
Edge 0 position Y
This is the Y coordinate of the measured
edge 0 position.
−
99,999.9999 to 99,999.9999
X1
Edge 1 position X
This is the X coordinate of the measured
edge 1 position.
−
99,999.9999 to 99,999.9999
Y1
Edge 1 position Y
This is the Y coordinate of the measured
edge 1 position.
−
99,999.9999 to 99,999.9999
TH
Angle (edge angle)
This is the measured angle.
−
180 to 180
SX0
Edg0 ref. pos. (edge 0
reference position X)
This is the X coordinate of the edge 0
position when it was registered.
−
99,999.9999 to 99,999.9999
SY0
Edg0 ref. pos. Y (edge
0 reference position
Y)
This is the Y coordinate of the edge 0
position when it was registered.
−
99,999.9999 to 99,999.9999
SX1
Edg1 ref. pos. X (edge
1 reference position
X)
This is the X coordinate of the edge 1
position when it was registered.
−
99,999.9999 to 99,999.9999
SY1
Edg1 ref. pos. Y (edge
1 reference position
Y)
This is the Y coordinate of the edge 1
position when it was registered.
−
99,999.9999 to 99,999.9999
STH
Reference angle
This is the angle when the edge was reg-
istered.
−
180 to 180
Expression text string
Data name
Description
Data range
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......