Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
FQ2-S4 User’s Manual
323
8
Controll
ing
Ope
rati
on a
nd Outputting
Data
wi
th
a
Para
llel
Co
nne
ctio
n
Input Signals
Teaching
This command uses the image that is currently being input to execute teaching for all of the registered
inspection items (except for Edge Pitch).
Parameters
Timing Chart
Output Signals
Signal
Function
IN0 to IN2
Turn OFF.
IN3
Turn ON.
IN4 and IN5 Turn OFF.
IN6
Turn ON.
IN7
This signal is the trigger for executing re-registration of the model and reference color. Set the IN0 to IN6 signals, wait for
at least 5 ms, and then turn ON the IN7 signal. The BUSY signal will be ON while the command is being executed.
Execution
Command
Input example
IN7
IN6
IN5
IN4
IN3
IN2
IN1
IN0
1
1001001
11001001
Signal
Function
RUN
This signal is ON while the Sensor is in Run Mode. It will be OFF in Setup Mode.
BUSY
This signal is ON while teaching is being executed.
ACK
When the command has been completed normally, this signal is turned ON for the time that is set for the ACK
output time.
0
IN7 signal
OFF
ON
OFF
ON
OFF
ON
RUN signal
OFF
ON
IN0 to IN6 signals
Run Mode entered.
Setup Mode entered.
BUSY signal
Command execution
1001001
Allow 5 ms min.
and then turn ON IN7.
ON for 1 ms min.
ACK signal
ACK output time
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......