5-3 Adjusting the Judgement Parameters
Adjusting Judgement Parameters While Looking at Measurement Results
If correct judgements are not possible, you can move directly from the Setup Mode display to the judgement
parameters display to make adjustments.
[Test] – [Continuous test] – (Either display)
Setting Up the Best Judgement Parameters Automatically
The judgement parameters of the selected inspection items can be automatically adjusted by using actual
workpieces which are considered as good and faulty products.
[Test]
−
[Continuous test]
1
Press [
]
−
[Adjust judgement] on the right of the
display.
2
Press the parameters and adjust the values of the
judgment conditions for them.
1
Move to the inspection item for which you want to au-
tomatically adjust the judgement parameters and
press [
] – [Adjust judgement] on the right side of
the display.
2
Press [
] – [Auto adjustment].
3
Display a sample image of a good object and press
[OK Teach]. Display a sample image of a bad object
and press [NG Teach].
4
Repeat these steps for at least three samples each.
5
Press [Back].
The best judgement parameters will be set automatically.
6
Press [OK].
Lower limit
Upper limit
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......