![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879163.webp)
Inspecting with the Sensitive Search Inspection Item
FQ2-S4 User’s Manual
4
Setting Up
Inspect
ions
161
Measurement Data That Can Be Logged
The following values can be logged as measurement data.
*
When logging data is output, the data is output in the order of the above table.
7-6 Logging Measurement Data and Image Data: p. 252
Errors
Errors in Teaching
A teaching error message will appear if the contrast of the image within the model registration region is too low.
Select a region with a larger contrast between light and dark areas compared to the region that was registered
as the model and re-register it as the model.
Parameter
Range of value
Description
Judgement
−
2: No judgement (not measured),
0: Judgement is OK,
−
1: Judgement is NG,
−
13: Teaching not performed error,
−
14: Figure not registered error,
−
15: Out of range error
This is the judgement result of the sensitive search.
Correlation
0 to 100
Correlation
D deviation
0 to 221
Density deviation
Position X
−
99,999.9999 to 99,999.9999
This is the X coordinate of the position where the model was found.
Position Y
−
99,999.9999 to 99,999.9999
This is the Y coordinate of the position where the model was found.
Angle
−
180 to 180
This is the angle of the position where the model was found.
NG sub-region
0 to 100
This is the number of NG sub-regions.
Sub-region number
0 to 99
This is the number of the regions with the lowest correlation.
Sub-region pos. X (sub-
region number (X))
0 to 9
This is the column number in the X direction of the output region.
Sub-region pos. Y (sub-
region number (Y))
0 to 9
This is the row number in the Y direction of the output region.
Sub-region position X
−
999,999,999.9999 to
999,999,999.9999
This is the X coordinate of the sub-region that was found.
Sub-region position Y
−
999,999,999.9999 to
999,999,999.9999
This is the Y coordinate of the sub-region that was found.
Correlation (sub-region)
0 to 100
Correlation
Deviation (sub-region)
0 to 221
Density deviation
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......