Changing the Scene to Change the Line Process
234
FQ2-S4 User’s Manual
7-1 Changing the Scene to Change the Line Process
What Are Scenes?
With an FQ2 Vision Sensor, the inspection items that can be processed at the same time are registered as
scenes. A command input from an external device or a touch panel operation can be used to select a certain
scene.
If a scene is registered for each type of measurement object or inspection, the line process can be changed
simply by changing the scene when the measurement object or inspection changes.
Example:
• Maximum Number of Scenes
With the FQ2-S4-series Vision Sensors, you can create up to 32 scenes.
• Settings Included with Scenes
The following settings are changed when the scene is changed: Camera image ([Image] Tab Page) and
Inspection Items ([Inspect] Tab Page). The settings related to external I/O specifications that are included in
the output settings and the system settings for the overall Sensor are used for all of the scenes.
Refer to the following information for the data that is included in the scene data.
Inspection for
product A
Inspection for
product B
Inspection for
product C
Inspection for
product Z
Scene 1
Scene 2
Scene 0
Scene 31
Line Process Changes:
Text alignment
(Inspection item 2: Edge Position)
Label detection
(Inspection item 1: Search)
These can be registered as
one scene.
Cap color
(Inspection item 0: Color Data)
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......