![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879424.webp)
Controlling Operation and Outputting Data with TCP No-protocol Communications
422
FQ2-S4 User’s Manual
●
ITEMDATA or ID
Acquire Inspection Item Data
This command acquires the parameters and measurement values of the specified inspection item.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Inspection item number
Specifies the inspection item number. (0 to 31)
External reference data
number
Specifies the external reference data number. (0 to 9999)
12-2 External Reference Parameters: p. 491
Acquired value
Returns the data for the specified inspection item.
12-2 External Reference Parameters: p. 491
I
T
D
A
T
A
CR
E
M
Inspection item number
(2 digits max.)
Command
Space
(0x20)
Space
(0x20)
Delimiter
Command
or
D
I
CR
Delimiter
Space
(0x20)
Space
(0x20)
External reference
data number
(4 digits max.)
Inspection item
number
(2 digits max.)
External reference
data number
(4 digits max.)
CR
Acquired
value
Delimiter
CR
O
K
CR
E
R
Delimiter
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......