Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
FQ2-S4 User’s Manual
437
Con
necting
throu
gh
Eth
e
rnet
9
Getting the Scene Number: 280F 00201000
This command acquires the scene number that is currently being used.
●
Format
●
Response Format
●
End Codes
●
Parameter Descriptions
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
28
0F
00201000
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
Scene number
(4 bytes)
28
0F
End code
00201000
Scene number that
was acquired
(2 digits max.)
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Scene number
Returns the acquired scene number (the number of the current scene).