![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879313.webp)
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
FQ2-S4 User’s Manual
311
8
Controll
ing
Ope
rati
on a
nd Outputting
Data
wi
th
a
Para
llel
Co
nne
ctio
n
●
Continuous Measurements
Example: Only Data 0 Set for Parallel Data Output
Timing Chart
1
The RUN signal turns ON when measurements are enabled and the Sensor is in Run Mode.
2
Turn ON IN7 while IN0 to IN6 are OFF. If this status is held while the BUSY signal is OFF, contin-
uous measurements will begin and the BUSY signal will remain ON while continuous measure-
ments are being performed.
3
When measurement results are output, the GATE signal is turned ON when the time that is set in
the [GATE ON delay] parameter in the communications settings has elapsed.
*1
4
The GATE signal is turned ON, and then the GATE signal is turned OFF when the time that is set
in the [Output time] parameter in the communications settings has elapsed.
*1
*1
Set the GATE ON delay and output time for the GATE signal so that the total time does not exceed the output period.
5
Continuous measurements end when the IN7 signal is turned OFF.
The ERROR signal will turn ON if the input command is not executed normally.
Set at least one data output for parallel judgement output and then read the OR signal when the GATE signal turns
ON.
Data 0
Data 0
Data 0
Output time
Output period
OFF
ON
D0 signal
GATE signal
GATE ON delay
Continuous measurements ended.
IN7 signal
OFF
ON
BUSY signal
OFF
ON
OR signal
ON while measurements are being processed
(depends on BUSY output conditions)
OFF
ON
OFF
ON
Allow 5 ms min. and then turn ON IN7.
Run Mode entered.
RUN signal
Setup Mode entered.
Measurements
executed.
Measurements
executed.
Turned ON when overall judgement is NG.
(Polarity of all output signals: Positive)
IN0 to IN6
signals are
OFF
Continuous
measurements
started.
Measurements
executed.
Measurements
executed.
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......