34.8.9. Data
Name:
DATA
Offset:
0x28
Reset:
0x0000
Property:
Write-Synchronized, Read-Synchronized
Bit
15
14
13
12
11
10
9
8
Access
Reset
Bit
7
6
5
4
3
2
1
0
DATA[7:0]
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
Bits 7:0 – DATA[7:0]: Data
The slave data register I/O location (DATA.DATA) provides access to the master transmit and receive
data buffers. Reading valid data or writing data to be transmitted can be successfully done only when
SCL is held low by the slave (STATUS.CLKHOLD is set). An exception occurs when reading the last data
byte after the stop condition has been received.
Accessing DATA.DATA auto-triggers I
2
C bus operations. The operation performed depends on the state
of CTRLB.ACKACT, CTRLB.SMEN and the type of access (read/write).
Writing or reading DATA.DATA when not in smart mode does not require synchronization.
Atmel SAM L22G / L22J / L22N [DATASHEET]
Atmel-42402E-SAM L22G / L22J / L22N_Datasheet_Complete-07/2016
719