Value
Name
Description
0x0
NO_EVT_OUTPUT No event output when using the resynchronized or synchronous path
0x1
RISING_EDGE
Event detection only on the rising edge of the signal from the event
generator
0x2
FALLING_EDGE
Event detection only on the falling edge of the signal from the event
generator
0x3
BOTH_EDGES
Event detection on rising and falling edges of the signal from the event
generator
Bits 9:8 – PATH[1:0]: Path Selection
These bits are used to choose which path will be used by the selected channel.
The path choice can be limited by the channel source, see the table in
.
Value
Name
Description
0x0
SYNCHRONOUS
Synchronous path
0x1
RESYNCHRONIZED
Resynchronized path
0x2
ASYNCHRONOUS
Asynchronous path
0x3
-
Reserved
Bits 6:0 – EVGEN[6:0]: Event Generator
These bits are used to choose the event generator to connect to the selected channel.
Value
Event Generator
Description
0x00
NONE
No event generator selected
0x01
OSCCTRL_CFD
Clock Failure Detection
0x02
OSC32KCTRL_CFD
Clock Failure Detection
0x03
RTC CMP0
Compare 0 (mode 0 and 1) or
Alarm 0 (mode 2)
0x04
RTC CMP1
Compare 1
0x05
RTC_TAMPER
Tamper Detection
0x06
RTC OVF
Overflow
0x07
RTC PER0
Period 0
0x08
RTC PER1
Period 1
0x09
RTC PER2
Period 2
0x0A
RTC PER3
Period 3
0x0B
RTC PER4
Period 4
0x0C
RTC PER5
Period 5
0x0D
RTC PER6
Period 6
0x0E
RTC PER7
Period 7
Atmel SAM L22G / L22J / L22N [DATASHEET]
Atmel-42402E-SAM L22G / L22J / L22N_Datasheet_Complete-07/2016
585