Figure 45-1. BOD Reset Behavior at Startup and Default Levels
VDDIN Voltage
Time
Internal State
Time
Vpot+
Vpot-
Internal Reset (active low)
Time
Under POR reset
Vpot+ Threshold reac hed
Under BOD reset
Vbod
+
Vbod
-
Vbod+ Threshold reached
Running
Update BOD33 Level
Update of BOD
level
Under BOD reset
Under BOD reset
Under POR reset
Update of BOD lev el
Running
Running
BOD Triggers a reset
BOD res et released
POR res et triggered
Vbod+ Threshold reached
Internal Reset (active high)
Time
Default BOD level #
1.6V
Default BOD level #
1.6V
User defined BOD level
with User Row content
Update BOD33 Level
with User Row content
BOD_THRESHOLD
POR_THRESHOLD
45.10.4. BOD33
Table 45-21. BOD33 Characteristics
(1)
Symbol
Parameters
Conditions
Min Typ. Max Unit
V
BOD+
BOD33 high threshold Level
V
BAT
level, Bod setting = 15
1.67 1.74 1.81 V
V
DD
level, Bod setting = 7
1.75 1.75 1.80
V
DD
level, Bod setting = 6 (default) 1.66 1.72 1.75
V
BAT
level, Bod setting = 55
2.80 2.90 3.01
V
DD
level, Bod setting = 39
2.65 2.87 2.95
V
BAT
level, Bod setting = 63
3.02 3.14 3.26
V
DD
level, Bod setting = 48
3.12 3.20 3.29
V
BOD-
/ V
BOD
BOD33 low threshold Level
V
BAT
level, Bod setting = 15
1.60 1.66 1.72 V
V
DD
level, Bod setting = 7
1.63 1.67 1.71
V
DD
level, Bod setting = 6
1.60 1.65 1.68
V
BAT
level, Bod setting = 55
2.70 2.81 2.92
V
DD
level, Bod setting = 39
2.70 2.77 2.84
V
BAT
level, Bod setting = 63
2.92 3.04 3.16
V
DD
level, Bod setting = 48
3.00 3.08 3.16
Step size
-
-
34
-
mV
Atmel SAM L22G / L22J / L22N [DATASHEET]
Atmel-42402E-SAM L22G / L22J / L22N_Datasheet_Complete-07/2016
1159