Symbol
Parameters
Conditions
Min Typ. Max Unit
V
HYS
Hysteresis (V
BOD+
- V
BOD-
)
BOD33.LEVEL = 0x0 to 0x3F
V
BAT
38
-
135 mV
V
DD
47
-
155 mV
T
START
Start-up time
Timing from enable to RDY
-
3.2
-
µs
Note:
1.
These values are based on characterization.
Table 45-22. Power Consumption
(1)
Symbol
Parameters
V
DD
(V)
Ta
Typ.
Max.
Units
I
DD
IDLE, Mode CONT
1.8
Max. 85°C Typ. 25°C
17.9
21.5
µA
3.3
28.8
33.1
IDLE, Mode SAMPL
1.8
0.020
0.306
µA
3.3
0.033
0.197
STDBY, Mode SAMPL
1.8
0.087
0.231
µA
3.3
0.114
0.347
Note:
1.
These values are based on characterization.
45.10.5. Analog-to-Digital (ADC) Characteristics
Table 45-23. Operating Conditions
Symbol
Parameters
Conditions
Min.
Typ.
Max.
Unit
RES
Resolution
-
-
12
bits
RS
Sampling rate
10
-
1000
kSPS
fs
Sampling clock
10
-
1000
kHz
Differential mode
Number of ADC clock cycles
SAMPCTRL.OFFCOMP=1
resolution 12bit (RESEL=0)
16
cycles
resolution 10bit (RESEL=2)
14
resolution 8bit (RESEL=3)
12
Differential mode
Number of ADC clock cycles
SAMPCTRL.OFFCOMP=0
SAMLPLEN
corresponds to
the decimal
value of the
SAMPLEN[5:0]
register
resolution
12bit
(RESEL=0)
SAMPLEN
+ 13
cycles
resolution
10bit
(RESEL=2)
SAMPLEN
+ 11
resolution
8bit
(RESEL=3)
SAMPLEN
+ 9
Atmel SAM L22G / L22J / L22N [DATASHEET]
Atmel-42402E-SAM L22G / L22J / L22N_Datasheet_Complete-07/2016
1160