6.6.15 D Registers Differring Depending on Conditions
D registers differring depending on the setting of the control type (CNT_L1)
Example: When CNT_L1 = 0, 1, 2, 5, 6, or 7, D0310 is D3005 (OL_L1_1) data.
When CNT_L1 = 3 or 4, D0310 is D3016 (OHc_L1_1) data.
Register
No.
Name of
GREEN
PID
PID control
ONOF
ON/OFF
control (1
point of
hysteresis)
ONOF2
ON/OFF
control (2
points of
hysteresis)
2P2L
Two-
position
two-level
control
H/C
Heating/
cooling
control
S-PI
Sample PI
control
BATCH
Batch PID
control
FFPID
Feedforward
control
CNT_L1: 0 CNT_L1: 1 CNT_L1: 2 CNT_L1: 3 CNT_L1: 4 CNT_L1: 5 CNT_L1: 6 CNT_L1: 7
D0310
1.OL
D3005 (OL_L1_1)
D3016 (OHc_L1_1)
D3005 (OL_L1_1)
D0335
2.OL
D3055 (OL_L1_2)
D3066 (OHc_L1_2)
D3055 (OL_L1_2)
D0360
3.OL
D3105 (OL_L1_3)
D3116 (OHc_L1_3)
D3105 (OL_L1_3)
D0385
4.OL
D3155 (OL_L1_4)
D3166 (OHc_L1_4)
D3155 (OL_L1_4)
D0410
5.OL
D3205 (OL_L1_5)
D3216 (OHc_L1_5)
D3205 (OL_L1_5)
D0435
6.OL
D3255 (OL_L1_6)
D3266 (OHc_L1_6)
D3255 (OL_L1_6)
D0460
7.OL
D3305 (OL_L1_7)
D3316 (OHc_L1_7)
D3305 (OL_L1_7)
D0485
8.OL
D3355 (OL_L1_8)
D3366 (OHc_L1_8)
D3355 (OL_L1_8)
D registers differring depending on the setting of the control type (CNT_L2)
Example: When CNT_L2 = 0, D0510 is D4105 (OL_L2_1) data.
When CNT_L2 = 4, D0510 is D4116 (OHc_L2_1) data.
Register No.
Name of
GREEN
PID
PID control
H/C
Heating/cooling control
CNT_L2: 0
CNT_L2: 4
D0510
1.OL
D4105 (OL_L2_1)
D4116 (OHc_L2_1)
D0535
2.OL
D4155 (OL_L2_2)
D4166 (OHc_L2_2)
D0560
3.OL
D4205 (OL_L2_3)
D4216 (OHc_L2_3)
D0585
4.OL
D4255 (OL_L2_4)
D4266 (OHc_L2_4)
D0610
5.OL
D4305 (OL_L2_5)
D4316 (OHc_L2_5)
D0635
6.OL
D4355 (OL_L2_6)
D4366 (
OHc_L2_6)
D0660
7.OL
D4405 (OL_L2_7)
D4416 (OHc_L2_7)
D0685
8.OL
D4455 (OL_L2_8)
D4466 (OHc_L2_8)
D registers differring depending on the setting of the control mode (CTLM)
Example: When CTLM = 1, 2, 3, 4, or 5, D0701 is 0.
When CTLM = 6, D0701 is PV.HL.
When CTLM = 7, D0701 is PV.AS.
Register
No.
Name of
GREEN
Single-
loop
control
Cascade
primary-
loop
control
Cascade
secondary-
loop
control
Cascade
control
Loop
control for
backup
Loop control with
PV switching
Loop control with
PV auto-selector
CTLM: 1 CTLM: 2 CTLM: 3 CTLM: 4 CTLM: 5
CTLM: 6
CTLM: 7
D0701
U1
0
0
0
0
0
D5205 (PV.HL)
D5208 (PV.AS)
D0702
U2
0
0
0
0
0
D5206 (PV.LL)
0
D0703
U3
0
0
0
0
0
D5207 (PV.2C)
0
Note: “0“ indicates on parameter specification. In communication, “0“ is returned.
6.6 GREEN Series Compatible D Registers