![YOKOGAWA UTAdvanced Series User Manual Download Page 198](http://html1.mh-extra.com/html/yokogawa/utadvanced-series/utadvanced-series_user-manual_3541677198.webp)
6-97
IM 05P07A01-01EN
Functions and
Applications of D Registers (for UT55A/UT52A/UP55A)
6
6.4 UT55A/UT52A/UP55A D Registers
Register
No.
Description
Range and meaning of value
D5723
EV1_L1
L
oop-1 EV1 display condition registration
Setting range: 4001 to 6304
OFF: Disable
4321: Link to alarm 1 (Lit when the alarm occurs)
4322: Link to alarm 2 (Lit when the alarm occurs)
4323: Link to alarm 3 (Lit when the alarm occurs)
4325: Link to alarm 4 (Lit when the alarm occurs)
4326: Link to alarm 5 (Lit when the alarm occurs)
4327: Link to alarm 6 (Lit when the alarm occurs)
4329: Link to alarm 7 (Lit when the alarm occurs)
4330: Link to alarm 8 (Lit when the alarm occurs)
4337: Link to Loop-2 alarm 1 (Lit when the alarm occurs) *
4338: Link to Loop-2 alarm 2 (Lit when the alarm occurs) *
4339: Link to Loop-2 alarm 3 (Lit when the alarm occurs) *
4341: Link to Loop-2 alarm 4 (Lit when the alarm occurs) *
4342: Link to Loop-2 alarm 5 (Lit when the alarm occurs) *
4343: Link to Loop-2 alarm 6 (Lit when the alarm occurs) *
4345: Link to Loop-2 alarm 7 (Lit when the alarm occurs) *
4346: Link to Loop-2 alarm 8 (Lit when the alarm occurs) *
4529: Heater break alarm 1 (Lit when the alarm occurs) *
4530: Heater break alarm 2 (Lit when the alarm occurs) *
*: For UT55A/UT52A only
5025 to 5027: Link to DI1-DI3 (Lit when the contact is closed)**
5041 to 5046: Link to DI11-DI16 (E1-terminal area) (Lit
when the contact is closed)**
5057 to 5062: Link to DI21-DI26 (E2-terminal area) (Lit
when the contact is closed)**
5073 to 5077: Link to DI31-DI35 (E3-terminal area) (Lit
when the contact is closed)**
5089 to 5094: Link to DI41-DI46 (E4-terminal area) (Lit
when the contact is closed)**
5153 to 5155: Link to AL1-AL3 (Lit when the contact is closed)**
5169 to 5173: Link to DO11-DO15 (E1-terminal area) (Lit
when the contact is closed)**
5185 to 5189: Link to DO21-DO25 (E2-terminal area) (Lit
when the contact is closed)**
5201 to 5205: Link to DO31-DO35 (E3-terminal area) (Lit
when the contact is closed)**
5217 to 5221: Link to DO41-DO45 (E4-terminal area) (Lit
when the contact is closed)**
**: Initial value. The contact action changes by the
setting of each "contact type" parameter.
4785: Link to PV event 1/local event-1 (Lit when occurs) ***
4786: Link to PV event 2/local event-2 (Lit when occurs) ***
4787: Link to PV event 3/local event-3 (Lit when occurs) ***
4789: Link to PV event 4/local event-4 (Lit when occurs) ***
4790: Link to PV event 5/local event-5 (Lit when occurs) ***
4791: Link to PV event 6/local event-6 (Lit when occurs) ***
4793: Link to PV event 7/local event-7 (Lit when occurs) ***
4794: Link to PV event 8/local event-8 (Lit when occurs) ***
4817: Link to time event 1 (Lit when occurs) ***
4818: Link to time event 2 (Lit when occurs) ***
4819: Link to time event 3 (Lit when occurs) ***
4821: Link to time event 4 (Lit when occurs) ***
4822: Link to time event 5 (Lit when occurs) ***
4823: Link to time event 6 (Lit when occurs) ***
4825: Link to time event 7 (Lit when occurs) ***
4826: Link to time event 8 (Lit when occurs) ***
4833: Link to time event 9 (Lit when occurs) ***
4834: Link to time event 10 (Lit when occurs) ***
4835: Link to time event 11 (Lit when occurs) ***
4837: Link to time event 12 (Lit when occurs) ***
4838: Link to time event 13 (Lit when occurs) ***
4839: Link to time event 14 (Lit when occurs) ***
4841: Link to time event 15 (Lit when occurs) ***
4842: Link to time event 16 (Lit when occurs) ***
***: For UP55A only
For other functions, see the Chapter 7 Functions and
Applications of I Relays (for UT55A/UT52A/UP55A).
D5724
EV2_L1
L
oop-1 EV2 display condition registration
D5725
EV3_L1
L
oop-1 EV3 display condition registration
D5726
EV4_L1
L
oop-1 EV4 display condition registration
D5727
EV5_L1
L
oop-1 EV5 display condition registration
D5728
EV6_L1
L
oop-1 EV6 display condition registration
D5729
EV7_L1
L
oop-1 EV7 display condition registration
D5730
EV8_L1
L
oop-1 EV8 display condition registration
D5731
EV1_L2
L
oop-2 EV1 display condition registration
D5732
EV2_L2
L
oop-2 EV2 display condition registration
D5733
EV3_L2
L
oop-2 EV3 display condition registration
D5734
EV4_L2
L
oop-2 EV4 display condition registration
D5735
EV5_L2
L
oop-2 EV5 display condition registration
D5736
EV6_L2
L
oop-2 EV6 display condition registration
D5737
EV7_L2
L
oop-2 EV7 display condition registration
D5738
EV8_L2
L
oop-2 EV8 display condition registration
Summary of Contents for UTAdvanced Series
Page 17: ...Blank Page...
Page 77: ...Blank Page...
Page 285: ...Blank Page...
Page 325: ...Blank Page...
Page 467: ...Blank Page...
Page 557: ...Blank Page...
Page 825: ...Blank Page...
Page 861: ...Blank Page...
Page 863: ...Blank Page...
Page 865: ...Blank Page...