4-90
7.
Disconnect the umbilical cable from the TC Amp board by pressing in on the tab and
pulling outward. See
Figure 4-153: TC Amp connector location
8.
Feed the umbilical cable out through the energy chain.
Installing the umbilical cable
1.
Feed the umbilical cable through the energy chain.
2.
Reconnect the umbilical cable to the TC Amp board.
3.
Reconnect the umbilical cable to the head board.
4.
Reconnect the umbilical cable to the I/O card.
5.
Reinstall the umbilical hose. See
Installing the umbilical hose on page
6.
Reinstall the upper electronics bay cover. See
Installing the upper electronics bay cover
7.
Reinstall the side panels. See
Installing the side panels on page
8.
Reinstall the top panel. See
Installing the top panel on page
Disconnect the
umbilical cable