4-94
Figure 4-158: Left side access panel mounting screw locations
4.
Using a
5
⁄
16
” nut driver or standard screwdriver, remove the 7 right side access panel
mounting screws and remove the right side access panel. See
Figure 4-159: Right side access panel mounting screw locations
5.
Using a
1
⁄
2
” box wrench, remove the X belt tension adjuster by loosening the inside nut
and then backing the bolt out of the mount. See
6.
Remove the tensioning fork and pulley from the X motor belt.
Figure 4-160: X belt tension adjustment bolt location
Remove the 7
mounting screws.
Remove the 7
mounting screws.
Loosen X belt
adjustment bolt