4-124
Figure 4-218: Left side rear Y guide rod mounting screw location
30.
Lift the front of the left Y guide rod upward until it is near the top of the frame.
31.
Rotate the left side Y guide rod towards the center of the printer and lower the guide rod.
32.
Pull the left side Y guide rod out towards the door opening.
33.
Angle the rest of the XY table out through the chamber door to remove from the printer.
Installing the XY table
1.
Insert the zero gauge block into the gauge. See
2.
Loosen the adjustment screw and slide the dial indicator assembly up or down to set the
‘zero’ reading: The large hand should be on 0 and the small hand on 5.
3.
Tighten the adjustment screw (do not over tighten the screw) and recheck the reading.
4.
Remove the zero block gauge block from the fixture.
Figure 4-219: Tension gauge zero setting
5.
Position the dial indicator on the top section of the Y-Drive belt at the center point of the
belt. See
Remove the left
rear Y guide rod
mounting screw
Adjustment screw
Zero gauge block
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...