4-78
Figure 4-130: Retaining clip location
8.
Disconnect the umbilical cable by pressing in on the tab and pulling upwards. See
Figure 4-131: Umbilical cable location
9.
Disconnect the model and support heater cables by pressing in on the tabs and pulling
Figure 4-132: Model and support heater cable locations
10.
Disconnect the toggle sensor cable from the head board by pressing in on the tab and
pulling outward. See
Remove the
thermocouple
wires from the
retaining clip
Disconnect
the umbilical
cable
Disconnect the
support side
heater cable
Disconnect the
model side
heater cable