5-44
9.
Move the XY table until the dial indicator is over the front right (FR) corner mark
Measure and record the difference (e.g. the dial indicator reads +0.010 in.).
10.
Move XY table until the dial indicator is over the back right (BR) corner mark
Measure and record the difference (e.g. the dial indicator reads +0.008
in).
11.
Enter the values that are written down into the XY level worksheet. Use the 8x6
worksheet for uPrint and uPrint SE, see
Use the 8x8 worksheet for uPrint
Plus and uPrint SE Plus, see
Figure 5-361: uPrint and uPrint SE measurement points and worksheet
BL
FL
FR
BR
Summary of Contents for uPrint