Performing part based calibration for uPrint Plus and uPrint SE Plus from the Service
Calibration menu
1.
While the printer is at
Idle
, enter standby mode by pressing the
Standby...
button.
2.
Enter the Service Calibration menu by pressing the following button sequence on the
display panel:
3,2,3,3,1
. See
Figure 5-313: Service Calibration button sequence
3.
Press the
Reset Part Based Calibration
button.
4.
The printer will ask “Do you want to zero settings and reboot?” Press
Yes
.
5.
Reboot the printer.
6.
Once the system displays Idle, press
Maintenance>System>Test Parts
then
select
the
test_XY_cal
part.
7.
When part is completed, remove from printer and let cool for five minutes.
8.
Locate the filled circle, this indicates the front of the substrate, see
Figure 5-314: Locating the Filled Circle (B)
Button 0
Button 1
Button 2
Button 3