uPrint/uPrint SE Service Manual
5-7
16.
Perform automatic XY tip calibration, see
Part Based Calibration
Required Tools
• Set of basic service tools
• 6”
digital
calipers
• MaracaEX
CD
Part based calibration consists of building a part and then taking six measurements - front,
right, left, rear, left rear and left front. These measurements are then entered using
MaracaEX.
When to Perform Part Based calibration
Part Based calibration needs to be performed after replacing the XY table assembly. Part
Based calibration is performed to eliminate any skewing in the X and Y axes.
Performing part based calibration for uPrint, uPrint SE, uPrint Plus and uPrint SE Plus from
the Service Calibration menu (Firmware version 9.1 or newer)
1.
While the printer is at
Idle
, enter standby mode by pressing the
Standby...
button.
2.
Enter the Service Calibration menu by pressing the following button sequence on the
display panel:
3,2,3,3,1
. See
Figure 5-281: Service Calibration button sequence
3.
Press the
Reset Part Based Calibration
button.
4.
The printer will ask “Do you want to zero settings and reboot?” Press
Yes
.
5.
Reboot the printer.
6.
Once the system displays Idle, press
Maintenance>System>Test Parts
then
select
the
test_XY_cal
part.
7.
When part is completed, remove from printer and let cool for five minutes.
Button 0
Button 1
Button 2
Button 3
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...