6-24
Controller Initialization Failed Minor Errors (19.XX)
Door Unlatch Failed (20.XX)
Controller Communications Failed Sub Errors (22.XX)
Universal Device Name Error (23.XX)
49.
18,04 Incorrect support head tem-
perature.
1.
Using MaracaEX, set support temperature to default of 300C.
18,05 Incorrect chamber tempera-
ture.
1.
Using MaracaEX, set chamber temperature to default of 77C.
Code Description
Corrective Actions
19,01 IN_COMMAND Rejected by
Controller.
Software use only
19,02 IN_COMMAND Time-out.
1.
Cycle power.
2.
Replace Controller Board.
3.
Replace Hard Drive.
Code Description
Corrective Actions
20,01 Unlatch command rejected.
20,02 Time-out period expired wait-
ing for head to stop.
1.
Check door latch solenoid wiring.
2.
Check ability of door to latch
Code Description
Corrective Actions
22,01 FC_SERVICE event not
received.
22,02 Insufficient material to com-
plete job.
Not used on uPrint, uPrint SE, uPrint Plus and uPrint SE Plus printers.
Code
Description
Corrective Actions
23,01 UDN controller command
failed.
23,02 UDN controller command
timed out.
1.
Check network for connectivity.
2.
Cycle power.
Code
Description
Corrective Actions
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...