5-42
“Get” .cal file – from the system hard drive to the calibration CD
1.
Obtain a new blank CD for writing the .cal file to.
2.
Remove the system calibration CD from the electronics bay and discard.
3.
Insert a new blank CD into the workstation CD drive.
4.
Install and open MaracaEX. Ensure that communication has been established with the
system.
5.
Select “Get” and browse to the CD drive.
6.
Select “Save” and the file will be written to the CD.
7.
Place the new CD into the CD envelope in the electronics bay.
Note:
This would typically be used after changing calibration values or if the .cal
file has not been stored on the CD.
Note:
Spaces are not allowed in the printer name.